Advances in New and Renewable Energy >
A New Method of Calculation Positive Sequence Voltage of Asymmetric Power Grid and its Application in Grid Connected Inverter
Received date: 2015-08-21
Revised date: 2015-09-25
Online published: 2015-10-30
A new method of calculation positive sequence voltage of asymmetric power grid and the application of the phase locked loop (PLL) based on dq transform is developed in this paper. Because of the negative sequence voltage component in power grid, the output of PLL is not accurate. According to the phase relationship between positive sequence and negative sequence, the trigonometric function method is proposed to extract positive sequence. This method is used in the three-phase voltage phase locked loop based on the dq synchronous reference frame transformation. The accuracy and stability of the PLL in the asymmetric power grid were improved by using this method. The importance of grid voltage feed forward for the control of the inverter was discussed. The advantages of the feed forward control by using positive sequence were analyzed. All the methods were improved in the experiments.
ZHANG Wei1,2, ZHANG Ji-yuan1,2, WANG Hao1, SHU Jie1, DING Jian-ning3 . A New Method of Calculation Positive Sequence Voltage of Asymmetric Power Grid and its Application in Grid Connected Inverter[J]. Advances in New and Renewable Energy, 2015 , 3(5) : 384 -390 . DOI: 10.3969/j.issn.2095-560X.2015.05.010
[1] 龚锦霞, 解大, 张延迟. 三相数字锁相环的原理及性能[J]. 电工技术学报, 2009, 24(10): 94-100.
[2] 王颢雄, 马伟明, 肖飞, 等. 双 dq 变换软件锁相环的数学模型研究[J]. 电工技术学报, 2011, 26(7): 238-24.
[3] RODRÍGUEZ P, POU J, BERGAS J, et al. Decoupled double synchronous reference frame PLL for power converters control[J]. IEEE Trans on Power Electronics, 2007, 22(2): 584-592.
[4] 张治俊, 李辉, 张煦, 等. 基于单/双同步坐标系的软件锁相环建模和仿真[J]. 电力系统保护与控制, 2011, 39(11): 138-144.
[5] 辛业春, 李国庆, 王尧, 等. 基于双dq坐标变换的三相电压锁相环的研究[J]. 电力系统保护与控制, 2014, 42(10): 114-118.
[6] RODRIGUEZ P, TEODORESCU R, CANDELA I, et al. New Positive-Sequence Voltage Detector For Grid Synchronization of Power Converters Under Faulty Grid Conditions: Power Electronics Specialists Conference[C]. PESC '06. 37th IEEE. 2006: 1-7.
[7] 袁旭峰, 程时杰, 文劲宇. 改进瞬时对称分量法及其在正负序电量检测中的应用[J]. 中国电机工程学报, 2008, 28(1): 52-58.
[8] 黄建明, 吴春华, 许富强. 基于相序解耦谐振控制器的基波正序电压相位检测方法[J]. 电网技术, 2013, 37(3): 667-672.
[9] 戴志威, 舒杰, 吴昌宏, 等. 基于LC滤波的光伏逆变器电感电流反馈控制策略研究[J]. 新能源进展, 2014(6): 449-453.
[10] ZMOOD D N, HOLMES D G. Stationary frame current regulation of PWM inverters with zero steady-state error[J]. Power Electronics IEEE Transactions on, 2003, 18(3): 814-822.
[11] 马琳, 金新民, 唐芬, 等. 三相并网逆变器比例谐振控制及其网压前馈问题分析[J]. 电工技术学报, 2012, 27(8): 56-63.
[12] 周德佳, 赵争鸣, 袁立强, 等. 300 kW光伏并网系统优化控制与稳定性分析[J]. 电工技术学报, 2008, 23(11): 116-122.
[13] MA L, JIN X, KEREKES T, et al. The PWM strategies of grid-connected distributed generation active NPC inverters: Energy Conversion Congress and Exposition[C]. ECCE 2009. IEEEIEEE, 2009: 920-927.
[14] HASANZADEH A, ONAR O C, MOKHTARI H, et al. A Proportional-Resonant Controller-Based Wireless Control Strategy With a Reduced Number of Sensors for Parallel-Operated UPSs[J]. IEEE Transactions on Power Delivery, 2010, 25: 468-478.
/
〈 |
|
〉 |