[1] technologies for low-energy buildings[J]. Future cities and environment, 2015, 1: 10. DOI: 10.1186/s40984- 015-0011-x.
[2] JABBARI-HICHRI A, BENNICI S, AUROUX A.Enhancing the heat storage density of silica-alumina by addition of hygroscopic salts (CaCl2, Ba(OH)2, and LiNO3)[J]. Solar energy materials and solar cells, 2015, 140: 351-360. DOI: 10.1016/j.solmat.2015.04.032.
[3] SHMROUKH A N, ALI A H H, OOKAWARA S. Adsorption working pairs for adsorption cooling chillers: a review based on adsorption capacity and environmental impact[J]. Renewable and sustainable energy reviews, 2015, 50: 445-456. DOI: 10.1016/j.rser.2015.05.035.
[4] SHARAFIAN A, FAYAZMANESH K, MCCAGUE C, et al.Thermal conductivity and contact resistance of mesoporous silica gel adsorbents bound with polyvinyl- pyrrolidone in contact with a metallic substrate for adsorption cooling system applications[J]. International journal of heat and mass transfer, 2014, 79: 64-71. DOI: 10.1016/j.ijheatmasstransfer.2014.07.086.
[5] 何兆红, 鲁涛, 黄宏宇, 等. 新型吸附床的研究进展[J]. 化学工程, 2011, 39(10): 34-38. DOI: 10.3969/j.issn. 1005-9954.2011.10.009.
[6] JIN Z Q, TIAN B, WANG L W, et al.Comparison on thermal conductivity and permeability of granular and consolidated activated carbon for refrigeration[J]. Chinese journal of chemical engineering, 2013, 21(6): 676-682. DOI: 10.1016/S1004-9541(13)60525-X.
[7] WANG L W, METCALF S J, CRITOPH R E, et al.Development of thermal conductive consolidated activated carbon for adsorption refrigeration[J]. Carbon, 2012, 50(3): 977-986. DOI: 10.1016/j.carbon.2011.09.061.
[8] ZHAO Y J, WANG L W, WANG R Z, et al.Study on consolidated activated carbon: choice of optimal adsorbent for refrigeration application[J]. International journal of heat and mass transfer, 2013, 67: 867-876. DOI: 10.1016/j.ijheatmasstransfer.2013.08.052.
[9] 吴永生. 船舶余热氨吸附式制冷混合吸附剂研制[D]. 厦门: 集美大学, 2014.
[10] MAURAN S, LEBRUN M, PRADES P, et al. Active composite and its use as reaction medium: 5283219[P].1994-02-01.
[11] TIAN B, JIN Z Q, WANG L W, et al.Permeability and thermal conductivity of compact chemical and physical adsorbents with expanded natural graphite as host matrix[J]. International journal of heat and mass transfer, 2012, 55(15/16): 4453-4459. DOI: 10.1016/j.ijheatmasstransfer. 2012.04.016.
[12] JIANG L, WANG L W, WANG R Z.Investigation on thermal conductive consolidated composite CaCl2 for adsorption refrigeration[J]. International journal of thermal sciences, 2014, 81: 68-75. DOI: 10.1016/j.ijthermalsci.2014.03.003.
[13] RESTUCCIA G, FRENI A, RUSSO F, et al.Experimental investigation of a solid adsorption chiller based on a heat exchanger coated with hydrophobic zeolite[J]. Applied thermal engineering, 2005, 25(10): 1419-1428. DOI: 10.1016/j.applthermaleng.2004.09.012.
[14] LI A, THU K, ISMAIL A B, et al.Performance of adsorbent-embedded heat exchangers using binder-coating method[J]. International journal of heat and mass transfer, 2016, 92: 149-157. DOI: 10.1016/j.ijheatmasstransfer.2015.08.097.
[15] CHANG K S, CHEN M T, CHUNG T W.Effects of the thickness and particle size of silica gel on the heat and mass transfer performance of a silica gel-coated bed for air-conditioning adsorption systems[J]. Applied thermal engineering, 2005, 25(14/15): 2330-2340. DOI: 10.1016/j.applthermaleng.2004.12.020.
[16] KIM C, CHO K, KIM S K, et al.Alumina-coated ordered mesoporous silica as an efficient and stable water adsorbent for adsorption heat pump[J]. Microporous and mesoporous materials, 2017, 239: 310-315. DOI: 10.1016/j.micromeso.2016.10.014.
[17] JEONG C K, KIM Y C, BAE K J, et al.Heat transfer characteristics of fin-tube heat exchanger coated with fapo zeolite adsorbent at different operating conditions[J]. Journal of the korean society for power system engineering, 2017, 21(3): 93-101.
[18] FRENI A, BONACCORSI L, CALABRESE L, et al.SAPO-34 coated adsorbent heat exchanger for adsorption chillers[J]. Applied thermal engineering, 2015, 82: 1-7. DOI: 10.1016/j.applthermaleng.2015.02.052.
[19] FRENI A, FRAZZICA A, DAWOUD B, et al.Adsorbent coatings for heat pumping applications: verification of hydrothermal and mechanical stabilities[J]. Applied thermal engineering, 2013, 50(2): 1658-1663. DOI: 10.1016/j.applthermaleng.2011.07.010.
[20] FRAZZICA A, FÜLDNER G, SAPIENZA A, et al. Experimental and theoretical analysis of the kinetic performance of an adsorbent coating composition for use in adsorption chillers and heat pumps[J]. Applied thermal engineering, 2014, 73(1): 1022-1031. DOI: 10.1016/j.applthermaleng.2014.09.004.
[21] WANG L L, HAN C, NADAGOUDA M N, et al.An innovative zinc oxide-coated zeolite adsorbent for removal of humic acid[J]. Journal of hazardous materials, 2016, 313: 283-290. DOI: 10.1016/j.jhazmat.2016.03.070.
[22] SANTAMARIA S, SAPIENZA A, FRAZZICA A, et al.Water adsorption dynamics on representative pieces of real adsorbers for adsorptive chillers[J]. Applied energy, 2014, 134: 11-19. DOI: 10.1016/j.apenergy.2014.07.053.
[23] ÇAĞLAR A, YAMALI C. Analysis of heat and mass transfer in the adsorbent bed of a thermal wave adsorption cooling cycle[J]. Computational thermal sciences: an international journal, 2013, 5(2): 97-106. DOI: 10.1615/computthermalscien.2013006349.
[24] ÇAĞLAR A. The effect of fin design parameters on the heat transfer enhancement in the adsorbent bed of a thermal wave cycle[J]. Applied thermal engineering, 2016, 104: 386-393. DOI: 10.1016/j.applthermaleng.2016.05.092.
[25] VERDE M, HARBY K, CORBERÁN J M. Optimization of thermal design and geometrical parameters of a flat tube-fin adsorbent bed for automobile air-conditioning[J]. Applied thermal engineering, 2017, 111: 489-502. DOI: 10.1016/j.applthermaleng.2016.09.099.
[26] JI X, LI M, FAN J Q, et al.Structure optimization and performance experiments of a solar-powered finned-tube adsorption refrigeration system[J]. Applied energy, 2014, 113: 1293-1300. DOI: 10.1016/j.apenergy.2013.08.088.
[27] 谢军, 王定标. 固体吸附式制冷系统新型针刺板吸附床数值模拟研究[J]. 制冷空调与电力机械, 2008(02): 36-38+50. DOI: 10.3969/j.issn.2095-3429.2008.02.010.
[28] REZK A R M, AL-DADAH R K. Physical and operating conditions effects on silica gel/water adsorption chiller performance[J]. Applied energy, 2012, 89(1): 142-149. DOI: 10.1016/j.apenergy.2010.11.021.
[29] NIAZMAND H, DABZADEH I.Numerical simulation of heat and mass transfer in adsorbent beds with annular fins[J]. International journal of refrigeration, 2012, 35(3): 581-593. DOI: 10.1016/j.ijrefrig.2011.05.013.
[30] NIAZMAND H, TALEBIAN H, MAHDAVIKHAH M.Bed geometrical specifications effects on the performance of silica/water adsorption chillers[J]. International journal of refrigeration, 2012, 35(8): 2261-2274. DOI: 10.1016/j.ijrefrig.2012.08.017.
[31] REZK A, AL-DADAH R K, MAHMOUD S, et al. Effects of contact resistance and metal additives in finned- tube adsorbent beds on the performance of silica gel/water adsorption chiller[J]. Applied thermal engineering, 2013, 53(2): 278-284. DOI: 10.1016/j.applthermaleng.2012.04.008.